Gas Fireplace Repair – My Main Burner Flame Will Not Turn On
This section will help you diagnose and fix simple issues related to your main burner flame. If you do not see a pilot light in your fireplace please refer to the Pilot Light Troubleshooting page. Also, if your main burner will run for a while, then go out, make sure your pilot stays lit. If your pilot goes out as well you can refer to the Pilot Light Issues tutorial.
Main burner issues can only be four things:
- The wall switch is bad
- Your pilot flame is bad
- Your thermopile is bad
- Your main control valve is bad
Again, thankfully, all of these issues can be easily tested, and most of them can be fixed very easily.
Wall switch issues
The most simple of these issues, and consequently the most common, is a bad wall switch. Every year I always get tons of service calls that are the result of a faulty wall switch. Again, this is probably the easiest thing to test and replace.
How does the wall switch affect the fireplace’s function?
Millivolt gas fireplaces have a pilot light that heats up a sensor (commonly called a thermocouple or thermopile). The thermopile and thermocouple generates electricity when heat is applied to it (not much, actually under 1 volt). This small amount of voltage is sent to the wall switch. When you flip the switch on, it will send that voltage back to the fireplace and signal to the fireplace to turn on the flame.
What can happen over the years, is that the connections inside the switch can get dirty, corroded, or broken, causing a loss of this voltage at the switch. So by the time the small amount of voltage gets sent back to the fireplace, it is not enough to signal the fireplace to turn on.
Testing the Wall switch
To test this, you will only need a screwdriver. First you will want to find the wall switch that turns on the fireplace. Again, this switch has less than 1 volt of electricity running through it, so there should be no issues with accidentally shocking yourself. However, you will want to make sure that you have located the switch that turns on your flame, NOT your FAN or NOT for anything else such as a LIGHT SWITCH. (You can always verify this after we take off the cover plate as just looking at the wiring should tell you what is what, but more on that later)
Next, we want to take our screwdriver and remove the cover plate:
You should just need to remove the two screws on the face plate with a flat head screwdriver.
Next, we should double check the wiring to make sure we have the right wall switch. We should just see two thin wires attached to the switch:
If it is a high voltage switch, we would see thicker wires and typically a ground wire like this:
If you are unsure, you can always turn off the circuit breaker for the room and make sure the power is turned off. You can also purchase a voltage tester to find out if there is power present.
Next, we want to unscrew the next two screws that hold the switch itself onto the receptacle box:
Once they have been unscrewed enough you should be able to pull the switch right out of the box. You want to be able to pull it out enough so that you can access the two wires on the side of the switch.
Now you’ll want to unscrew the screws that the wires are attached to. Again, you only need to unscrew them enough to be able to pull the wires off.
Once you have the wires removed from the wall switch itself, all we are going to do is touch the wires together. This is basically just bypassing the wall switch and if the fireplace comes on, this should tell us right away that the old wall switch is bad. If it is bad you should replace it with any single pole wall switch (you can buy these here or pick these up at any home improvement or hardware store). You’ll probably want to bring the old wall switch with so that you can stick with the same color and that it will match with the rest of the house:
If your fireplace still does not come on by bypassing the wall switch, the next step is what we call “jumping the valve”. To do this, you will just need to take a wire (a paperclip works great) and complete the connecting between the TH and TP/TH terminals on the valve.
Place one end of the paperclip on the TH terminal and the other on the TP/TH terminal:
By doing this you are essentially bypassing the wall switch and any wall switch wiring, extra toggle switches, safety switches, and/or safety limit switches in the fireplace. If the fireplace comes on when jumping the valve, you know that there must be something wrong with one or all of these items.
For additional ways to test your wall switch and/or wiring, here is a short video tutorial from Fire-Parts.com that goes over this process:
November 14, 2012
i chand thermopile wall swich mainbur flame not come on
November 15, 2012
How is your pilot flame? Does it engulf the thermopile completely? If your pilot flame looks very yellow (instead of blue) or it is not wrapping around your thermopile sensor you may need to replace the entire assembly.
November 14, 2012
i chand thermopile wall swich mainbur flame not come on
November 15, 2012
How is your pilot flame? Does it engulf the thermopile completely? If your pilot flame looks very yellow (instead of blue) or it is not wrapping around your thermopile sensor you may need to replace the entire assembly.
January 11, 2013
No gas comes out of control valve…I do not have a basement; what could the problem be?
January 19, 2013
Make sure there is gas going IN to the control valve. Find any “shut-off” valves on the gas line going to the fireplace and make sure they are turned on (parallel with the gas line). They are usually located in your basement but if you do not have a basement, check your furnace room. If the fireplace runs on propane, make sure your tank is not turned off or empty.
January 11, 2013
No gas comes out of control valve…I do not have a basement; what could the problem be?
January 19, 2013
Make sure there is gas going IN to the control valve. Find any “shut-off” valves on the gas line going to the fireplace and make sure they are turned on (parallel with the gas line). They are usually located in your basement but if you do not have a basement, check your furnace room. If the fireplace runs on propane, make sure your tank is not turned off or empty.
January 17, 2013
So every winter it seems like something goes wrong with our gas fireplace. Money is super tight right now so I decided to goggle how to fix it myself and found this page. Turns out it was the wall switch. Took me 5 minutes to fix. Thank you for this page.
January 23, 2013
Awesome, glad to help! Thanks for your comment.
October 25, 2013
Mine too, it’s the wall switch. This saves me some money. Thank you so much.
January 17, 2013
So every winter it seems like something goes wrong with our gas fireplace. Money is super tight right now so I decided to goggle how to fix it myself and found this page. Turns out it was the wall switch. Took me 5 minutes to fix. Thank you for this page.
January 23, 2013
Awesome, glad to help! Thanks for your comment.
October 25, 2013
Mine too, it’s the wall switch. This saves me some money. Thank you so much.
January 21, 2013
I can lit the pilot, the pilot light is on, when I turn it to on position. The pilot light is off right away. What is wrong with it? I need help to fix my fireplace, thanks. Ming.
January 23, 2013
This sounds like you have a honeywell valve that commonly had this problem. Try turning the knob to the “on” position VERY SLOWLY. Many times this will keep the pilot going. A permanent fix would be to replace the valve. However, if it is the valve I’m thinking of it has been discontinued and can be hard to find.
January 21, 2013
I can lit the pilot, the pilot light is on, when I turn it to on position. The pilot light is off right away. What is wrong with it? I need help to fix my fireplace, thanks. Ming.
January 23, 2013
This sounds like you have a honeywell valve that commonly had this problem. Try turning the knob to the “on” position VERY SLOWLY. Many times this will keep the pilot going. A permanent fix would be to replace the valve. However, if it is the valve I’m thinking of it has been discontinued and can be hard to find.
February 4, 2013
To the techs of mygasfireplacerepair, Thank you
so much for your troubleshooting advise. I followed
the steps above for switch issues and found out the switch
was bad which was causing the main unit not to light.As a homemaker I was determined to fix this myself and with your expert advise I did it. Thank you very much.
February 23, 2013
Glad to help. Please share this site with your friends!
February 4, 2013
To the techs of mygasfireplacerepair, Thank you
so much for your troubleshooting advise. I followed
the steps above for switch issues and found out the switch
was bad which was causing the main unit not to light.As a homemaker I was determined to fix this myself and with your expert advise I did it. Thank you very much.
February 23, 2013
Glad to help. Please share this site with your friends!
February 18, 2013
I can see my pilot light so im guessing it’s my wall switch that needs to be checked out. The wallswitch is actually a thermostat though, can i still remove the panel?
February 19, 2013
Yes. Fireplace thermostats work the same way as wall switches, except they turn on and off with the temperature instead of by someone flipping them on or off. You can pull the front off the thermostat to find where the wires are hooked up. Take the wires off the terminals and connect them together just like bypassing the wall switch in the tutorial.
February 18, 2013
I can see my pilot light so im guessing it’s my wall switch that needs to be checked out. The wallswitch is actually a thermostat though, can i still remove the panel?
February 19, 2013
Yes. Fireplace thermostats work the same way as wall switches, except they turn on and off with the temperature instead of by someone flipping them on or off. You can pull the front off the thermostat to find where the wires are hooked up. Take the wires off the terminals and connect them together just like bypassing the wall switch in the tutorial.
February 20, 2013
I have a healthy blue pilot light, but the switch does not start the burner. I tested my switch and it seems to be fine and didn’t start the flame when I connected the wires. What is my next step?
February 23, 2013
Make sure your valve is in the “on” position and not the “pilot” position. Then, test the voltage on your thermopile (you can find the tutorial for this on this site as well). If your Thermopile voltage looks ok: we can jump the valve directly. Find where your wall switch hooks on to the valve. There are usually 3 terminals on the valve and the wall switch will connect to the outer terminals (these say “TH” next to them). If you connect a wire from the top to the bottom terminals (completing the connected between the TH terminals) it should come on.
November 11, 2013
When I jump the two outer terminals the main burner does come on. So what is not working? Thanks!
November 12, 2013
Follow the tutorial and you will find out!
November 12, 2013
I left the stove running and it stopped after an hour and now wont start by jumping. I still have 638 mv across the terminals. Thanks!
November 14, 2013
What happens to the voltage when you jump it?
February 20, 2013
I have a healthy blue pilot light, but the switch does not start the burner. I tested my switch and it seems to be fine and didn’t start the flame when I connected the wires. What is my next step?
February 23, 2013
Make sure your valve is in the “on” position and not the “pilot” position. Then, test the voltage on your thermopile (you can find the tutorial for this on this site as well). If your Thermopile voltage looks ok: we can jump the valve directly. Find where your wall switch hooks on to the valve. There are usually 3 terminals on the valve and the wall switch will connect to the outer terminals (these say “TH” next to them). If you connect a wire from the top to the bottom terminals (completing the connected between the TH terminals) it should come on.
November 11, 2013
When I jump the two outer terminals the main burner does come on. So what is not working? Thanks!
November 12, 2013
Follow the tutorial and you will find out!
November 12, 2013
I left the stove running and it stopped after an hour and now wont start by jumping. I still have 638 mv across the terminals. Thanks!
November 14, 2013
What happens to the voltage when you jump it?
February 22, 2013
My gas fireplace is 2 years old. The pilot light is on and blue but the main burner will not come on at all. I took the switch apart and checked the switch twice and it is definitely not that. I also checked the voltage on the thermopile like you mentioned. It was at 840mV and did not budge when I flipped the switch. So I am out of options. Any idea what is wrong??
February 23, 2013
Make sure your valve is in the “on” position and not the “pilot” position. We can also jump the valve directly in case the issue is in the wiring. Find where your wall switch hooks on to the valve. There are usually 3 terminals on the valve and the wall switch will connect to the outer 2 terminals (these say “TH” next to them). If you connect a single wire to these terminals (completing the connection between the TH terminals) it should come on. If it doesn’t you should at least see a change in voltage. It it drops to 0, there is a short in your thermopile. If it still doesn’t drop at all, it could be your valve.
February 22, 2013
My gas fireplace is 2 years old. The pilot light is on and blue but the main burner will not come on at all. I took the switch apart and checked the switch twice and it is definitely not that. I also checked the voltage on the thermopile like you mentioned. It was at 840mV and did not budge when I flipped the switch. So I am out of options. Any idea what is wrong??
February 23, 2013
Make sure your valve is in the “on” position and not the “pilot” position. We can also jump the valve directly in case the issue is in the wiring. Find where your wall switch hooks on to the valve. There are usually 3 terminals on the valve and the wall switch will connect to the outer 2 terminals (these say “TH” next to them). If you connect a single wire to these terminals (completing the connection between the TH terminals) it should come on. If it doesn’t you should at least see a change in voltage. It it drops to 0, there is a short in your thermopile. If it still doesn’t drop at all, it could be your valve.
March 11, 2013
Same problem I have been seeing here. Pilot on and nothing else. Our switch is part of the main frame of the fireplace. We have someone coming out as we (seniors) are not able to accomplish your suggestions. I’m sure the fireplace needs a cleaning but we don’t actually use it much. My problem is the charges seem so expensive. I sure don’t want something replaced if it is not necessary. This sight has been so very helpful. And I am sure so many people are using your suggestions. I thank you in adance for any advice.
Thanks
March 11, 2013
Same problem I have been seeing here. Pilot on and nothing else. Our switch is part of the main frame of the fireplace. We have someone coming out as we (seniors) are not able to accomplish your suggestions. I’m sure the fireplace needs a cleaning but we don’t actually use it much. My problem is the charges seem so expensive. I sure don’t want something replaced if it is not necessary. This sight has been so very helpful. And I am sure so many people are using your suggestions. I thank you in adance for any advice.
Thanks
April 13, 2013
Propane gas fireplace insert lights & stays on maybe 10-15 minutes & then turns itself off. Turned back on flame shoots very high, after few minutes, turns itself off again.
Gas company people checked it twice, cleaned burners & can’t find anything wrong! But, problem still exists…
Help!
April 30, 2013
Have you checked the wall switch? When it turns on, does the pilot go out, or does it stay lit?
October 26, 2013
so, someone else has fireplace that won’t stay lit.
April 13, 2013
Propane gas fireplace insert lights & stays on maybe 10-15 minutes & then turns itself off. Turned back on flame shoots very high, after few minutes, turns itself off again.
Gas company people checked it twice, cleaned burners & can’t find anything wrong! But, problem still exists…
Help!
April 30, 2013
Have you checked the wall switch? When it turns on, does the pilot go out, or does it stay lit?
October 26, 2013
so, someone else has fireplace that won’t stay lit.
June 30, 2013
My pilot light is on, and is blue and moving a little like it should. It will not light though. I have removed the wall switch and touched the 2 wires together. Still doesnt light. The valve is turned on. What do I try next
July 8, 2013
Use a digital multimeter and test the voltage on your thermopile sensor. Click on “Part II: How to test your
Thermopile sensor” on the bottom of the post.
June 30, 2013
My pilot light is on, and is blue and moving a little like it should. It will not light though. I have removed the wall switch and touched the 2 wires together. Still doesnt light. The valve is turned on. What do I try next
July 8, 2013
Use a digital multimeter and test the voltage on your thermopile sensor. Click on “Part II: How to test your
Thermopile sensor” on the bottom of the post.
July 5, 2013
According to the gas company I have a main control value that seems to be leaking gas out of the value that is used to light the pilot and turn on the gas. He said there is a spring loaded value that should prevent the gas from leaking out of the valve stem. Although difficult, he said this could be removed cleaned and repaired, rather than replaced. This is a older majestic unit GS28A made in the 1970’s and a replacement control valve is not available. Is there anyway to get ahold of a parts diagram for the control valve?
July 8, 2013
I’m not aware of a GS28A. Is it possible it is a GF28A? If so, you can still buy these valves online. HONEYWELL VS820A1054 Valve, NG or VS820A-1336, Propane. Here is a link to replacement parts on the valve: https://customer.honeywell.com/en-US/pages/product.aspx?cat=HonECC%20Catalog&pid=VS820A1054/U
July 5, 2013
According to the gas company I have a main control value that seems to be leaking gas out of the value that is used to light the pilot and turn on the gas. He said there is a spring loaded value that should prevent the gas from leaking out of the valve stem. Although difficult, he said this could be removed cleaned and repaired, rather than replaced. This is a older majestic unit GS28A made in the 1970’s and a replacement control valve is not available. Is there anyway to get ahold of a parts diagram for the control valve?
July 8, 2013
I’m not aware of a GS28A. Is it possible it is a GF28A? If so, you can still buy these valves online. HONEYWELL VS820A1054 Valve, NG or VS820A-1336, Propane. Here is a link to replacement parts on the valve: https://customer.honeywell.com/en-US/pages/product.aspx?cat=HonECC%20Catalog&pid=VS820A1054/U
August 28, 2013
Hello, I have a Superior brand electric fireplace. Pilot will light and stay lit but main burner won’t always come on when I flip the wall switch. I tried removing the switch and touching the two wires together and nothing still. Replaced switch anyway and still nothing. Replaced thermopile and put things back together and it lit right away. Three days later I tried it again and nothing? You can hear that the gas valve is not opening when the switch is flipped. I have a nice blue pilot but it is not “engulfing” the thermopile completely. It is touching one side of it only. I heated up the thermopile with a lighter when the switch wouldn’t work and tried it again and it immediately came on. I also tried jumping the two “th” terminals together with a jumper wire and it immediately came on also. Could this be an issue with the pilot assembly? Seems like the main valve is ok but maybe the pilot isn’t heating the thermopile enough? Any help is appreciated. Thanks in advance!
August 29, 2013
It sounds like its something in the wiring between the wall switch and the valve (especially if you get get it to come on by jumping the valve directly). Check to make sure your wall switch wires are securely on the terminals and that any connectors on those wires are still good. Otherwise the next step would be to get a Digital Multimeter and start testing your thermopile voltage.
August 30, 2013
Thanks so much for the advice. I will check the wiring/connectors tomorrow morning and let you know what I find out. I do have a multi-meter and attempted to check the voltage of the thermopile but wasn’t really sure which setting to have it on as it is different from the one that you show in the tutorials. I don’t have much experience using one so I will probably have a couple questions re: that if the wiring doesn’t solve my problem. Thanks for what you do for us on this site. It is much appreciated!
August 28, 2013
Hello, I have a Superior brand electric fireplace. Pilot will light and stay lit but main burner won’t always come on when I flip the wall switch. I tried removing the switch and touching the two wires together and nothing still. Replaced switch anyway and still nothing. Replaced thermopile and put things back together and it lit right away. Three days later I tried it again and nothing? You can hear that the gas valve is not opening when the switch is flipped. I have a nice blue pilot but it is not “engulfing” the thermopile completely. It is touching one side of it only. I heated up the thermopile with a lighter when the switch wouldn’t work and tried it again and it immediately came on. I also tried jumping the two “th” terminals together with a jumper wire and it immediately came on also. Could this be an issue with the pilot assembly? Seems like the main valve is ok but maybe the pilot isn’t heating the thermopile enough? Any help is appreciated. Thanks in advance!
August 29, 2013
It sounds like its something in the wiring between the wall switch and the valve (especially if you get get it to come on by jumping the valve directly). Check to make sure your wall switch wires are securely on the terminals and that any connectors on those wires are still good. Otherwise the next step would be to get a Digital Multimeter and start testing your thermopile voltage.
August 30, 2013
Thanks so much for the advice. I will check the wiring/connectors tomorrow morning and let you know what I find out. I do have a multi-meter and attempted to check the voltage of the thermopile but wasn’t really sure which setting to have it on as it is different from the one that you show in the tutorials. I don’t have much experience using one so I will probably have a couple questions re: that if the wiring doesn’t solve my problem. Thanks for what you do for us on this site. It is much appreciated!
September 9, 2013
I still haven’t diagnosed the problem with the main burner inconsistency. I had a question for you though. Sometimes when I flip the switch it comes right on. Other times, I don’t hear the gas valve open and nothing happens. A few times when the main burner failed to come on after flipping the switch I tried some tests. A couple times, I heated the thermopile with a log lighter and it opened right up and the burner came right on. Other times, I jumped the th terminals directly taking the switch out of the equation and I had the same response where the burner opened immediately and came right on. My question is how do I know if this is a switch wire issue or an issue with the thermopile not getting hot enough to generate the 1/2 volt or so required to open the gas valve? It is a brand new thermopile so I don’t think that is the issue. I need to get this fixed as I am selling the house and want to figure this problem out before the home inspection next week. Thanks again in advance
September 9, 2013
The only way to know for sure is to test the voltage on the TP terminals to make sure you are getting enough voltage out of the thermopile. Also, if the voltage changes after hitting the switch (or doesn’t change) that can tell you a lot about whats going on as well.
You could check the wall switch connections on to the valve. Sometimes the connectors are bad or loose, or its possible the wall switch wire runs to a little toggle switch underneath the fireplace before hooking on to the valve; you could wire the wall switch wire directly to the valve.
September 10, 2013
Thanks for the ideas. The way that my switch is wired makes it really difficult to run a new wire as it is routed out the opposite side as to which the switch is located. Also, I noticed that the wiring is similar to the wire on the thermopile in that it seems to have a sheath to protect it from the heat. I am not sure where to even get this type of wire? I could run a couple temporary wires to a switch right off the gas valve and out the front of the fireplace to at least do a test to rule out this problem though? Also, If you could run down how to test the tp terminals correctly. If you could advise me which setting to use on the multimeter to test and what values I am looking for that would be a huge help! Thanks in advance for what you do here! Cheers
September 17, 2013
You want to find the DC voltage part of the meter and put it on the lowest setting (this will detect electricity under 1 volt). Then go to the “How to test your Thermopile Section” to troubleshoot.
September 9, 2013
I still haven’t diagnosed the problem with the main burner inconsistency. I had a question for you though. Sometimes when I flip the switch it comes right on. Other times, I don’t hear the gas valve open and nothing happens. A few times when the main burner failed to come on after flipping the switch I tried some tests. A couple times, I heated the thermopile with a log lighter and it opened right up and the burner came right on. Other times, I jumped the th terminals directly taking the switch out of the equation and I had the same response where the burner opened immediately and came right on. My question is how do I know if this is a switch wire issue or an issue with the thermopile not getting hot enough to generate the 1/2 volt or so required to open the gas valve? It is a brand new thermopile so I don’t think that is the issue. I need to get this fixed as I am selling the house and want to figure this problem out before the home inspection next week. Thanks again in advance
September 9, 2013
The only way to know for sure is to test the voltage on the TP terminals to make sure you are getting enough voltage out of the thermopile. Also, if the voltage changes after hitting the switch (or doesn’t change) that can tell you a lot about whats going on as well.
You could check the wall switch connections on to the valve. Sometimes the connectors are bad or loose, or its possible the wall switch wire runs to a little toggle switch underneath the fireplace before hooking on to the valve; you could wire the wall switch wire directly to the valve.
September 10, 2013
Thanks for the ideas. The way that my switch is wired makes it really difficult to run a new wire as it is routed out the opposite side as to which the switch is located. Also, I noticed that the wiring is similar to the wire on the thermopile in that it seems to have a sheath to protect it from the heat. I am not sure where to even get this type of wire? I could run a couple temporary wires to a switch right off the gas valve and out the front of the fireplace to at least do a test to rule out this problem though? Also, If you could run down how to test the tp terminals correctly. If you could advise me which setting to use on the multimeter to test and what values I am looking for that would be a huge help! Thanks in advance for what you do here! Cheers
September 17, 2013
You want to find the DC voltage part of the meter and put it on the lowest setting (this will detect electricity under 1 volt). Then go to the “How to test your Thermopile Section” to troubleshoot.
September 12, 2013
I have a gas fireplace. However, I can get the pilot light lite and put it in the on position and it stays lite but the burners will not ignite. The flame is blue/yellow and I have not seen a switch, there is just a valve that is hooked to the gas line on the back of the unit. A friend of mine took it apart to check everything and clean what he could and the burners will still not ignite. I’m in desperate need of advice because its getting cold and this is what heats my house.
September 12, 2013
I have a gas fireplace. However, I can get the pilot light lite and put it in the on position and it stays lite but the burners will not ignite. The flame is blue/yellow and I have not seen a switch, there is just a valve that is hooked to the gas line on the back of the unit. A friend of mine took it apart to check everything and clean what he could and the burners will still not ignite. I’m in desperate need of advice because its getting cold and this is what heats my house.
October 12, 2013
I have a gas fireplace whose pilot is controlled by a wall switch. Neither the pilot nor flame come on. I did a continuity test on the switch and when it turned on, there was continuity. I didn’t try connecting the wires to see if that would start the fireplace. If the switch has continuity, do I need to put the wires together to bypass the switch, or should I go on and trouble shoot the rest? At this point, gas gets to the fireplace, but doesn’t come out to the logs. What should I check?
October 23, 2013
it sounds like you have an electronic ignition system, you’ll need to make sure you have power to the fireplace. Watch this video to see if you have an electronic system.
October 12, 2013
I have a gas fireplace whose pilot is controlled by a wall switch. Neither the pilot nor flame come on. I did a continuity test on the switch and when it turned on, there was continuity. I didn’t try connecting the wires to see if that would start the fireplace. If the switch has continuity, do I need to put the wires together to bypass the switch, or should I go on and trouble shoot the rest? At this point, gas gets to the fireplace, but doesn’t come out to the logs. What should I check?
October 23, 2013
it sounds like you have an electronic ignition system, you’ll need to make sure you have power to the fireplace. Watch this video to see if you have an electronic system.
October 23, 2013
thank you! just taking the wall plate off the switch and checking that the wires were tight saved me $$! just loose…tightened up and presto!
electricity + gas = scary. I was worried to try the first thing to troubleshoot. Thanks for this info!
Other good stuff on this site too! a thermo-what?!
I’ll visit here with any more ?’s.
Thanks again!
October 23, 2013
Awesome! Thanks for your comment!
October 23, 2013
thank you! just taking the wall plate off the switch and checking that the wires were tight saved me $$! just loose…tightened up and presto!
electricity + gas = scary. I was worried to try the first thing to troubleshoot. Thanks for this info!
Other good stuff on this site too! a thermo-what?!
I’ll visit here with any more ?’s.
Thanks again!
October 23, 2013
Awesome! Thanks for your comment!
October 23, 2013
I have a Mendota fireplace model DXV-111-36N I replaced the thermopile and I still can not get the burner to come on. The pilot comes on and is blue and around the thermopile. This unit runs by remote, I disconnected the remote and jumped the main valve and it blows the pilot out. It’s an older unit, could the main valve went bad?
October 23, 2013
Are you sure you are jumping the right terminals? You’ll need to jump the outer two terminals. If you accidentally jump the terminals with the thermopile, it will short the pilot out.
What kind of voltage are you getting on the thermopile?
October 23, 2013
I don’t get a reading at all
October 23, 2013
I just jumped the out side and nothing happened The pilot stated lit
October 23, 2013
I have a Mendota fireplace model DXV-111-36N I replaced the thermopile and I still can not get the burner to come on. The pilot comes on and is blue and around the thermopile. This unit runs by remote, I disconnected the remote and jumped the main valve and it blows the pilot out. It’s an older unit, could the main valve went bad?
October 23, 2013
Are you sure you are jumping the right terminals? You’ll need to jump the outer two terminals. If you accidentally jump the terminals with the thermopile, it will short the pilot out.
What kind of voltage are you getting on the thermopile?
October 23, 2013
I don’t get a reading at all
October 23, 2013
I just jumped the out side and nothing happened The pilot stated lit
October 23, 2013
No clicking be the valve either
October 23, 2013
If your voltage is 0, that means there is a short in your thermopile. When your thermopile heats up, it should always create a minimum of 300 millivolts or higher. Try testing the voltage with it disconnected on the valve to be sure.
October 23, 2013
No clicking be the valve either
October 23, 2013
If your voltage is 0, that means there is a short in your thermopile. When your thermopile heats up, it should always create a minimum of 300 millivolts or higher. Try testing the voltage with it disconnected on the valve to be sure.
October 23, 2013
Not hooked up I get .3 Maybe my meter is screwed up?
October 27, 2013
Sounds like you don’t have your meter in the lowest setting. This looks like 300 something millivolts. If it drops to zero when you turn the fireplace on, you have a short in your thermopile
October 23, 2013
Not hooked up I get .3 Maybe my meter is screwed up?
October 27, 2013
Sounds like you don’t have your meter in the lowest setting. This looks like 300 something millivolts. If it drops to zero when you turn the fireplace on, you have a short in your thermopile
October 25, 2013
Just moved into a house and it has a Heat N glo Sl-750TR. I vacuumed all the dust out. I then got the pilot light lit and it is nice and blue. The only problem I have is the flames once it is turned on seem low. I then turned it off and let it cool and removed the plate with all the holes and blew the soot out with air. Flames still low. I looked and it doesn’t have an adjustable knob for the flame. Is there anything I can do?
Thank you
October 27, 2013
The Slimline series (SL-750TR, SL-550TR) are lower BTU fireplaces. They are not designed to have a large flame.
Many times, it will take the fireplace around an hour before the flame will turn more yellow and look its best.
If you think that there still is an issue with the flame height, its possible you might have some blockage in the burner tube. There is a certain spider that likes the smell of the natural gas additive (that sulfur gas smell) and will often build a nest in the main burner tube.
To clear the blockage you usually have to remove the logs and burner to find the burner orifice (it is usually brass in color and looks like a bullet). Take a piece of wire and run it through the orifice and down the tube to clear out any blockage. If it is down far enough you may have to remove it from the valve itself.
October 25, 2013
Just moved into a house and it has a Heat N glo Sl-750TR. I vacuumed all the dust out. I then got the pilot light lit and it is nice and blue. The only problem I have is the flames once it is turned on seem low. I then turned it off and let it cool and removed the plate with all the holes and blew the soot out with air. Flames still low. I looked and it doesn’t have an adjustable knob for the flame. Is there anything I can do?
Thank you
October 27, 2013
The Slimline series (SL-750TR, SL-550TR) are lower BTU fireplaces. They are not designed to have a large flame.
Many times, it will take the fireplace around an hour before the flame will turn more yellow and look its best.
If you think that there still is an issue with the flame height, its possible you might have some blockage in the burner tube. There is a certain spider that likes the smell of the natural gas additive (that sulfur gas smell) and will often build a nest in the main burner tube.
To clear the blockage you usually have to remove the logs and burner to find the burner orifice (it is usually brass in color and looks like a bullet). Take a piece of wire and run it through the orifice and down the tube to clear out any blockage. If it is down far enough you may have to remove it from the valve itself.
October 27, 2013
I have a natural gas ventless fireplace with a pilot light. The fireplace will light when the wall switch is turned on, and the burners will stay lit for anywhere from 30mins to a few hours. Then they will go out. The burners will come back on just by flipping the switch off then back on. Any advice?
October 28, 2013
Replace the switch
October 27, 2013
I have a natural gas ventless fireplace with a pilot light. The fireplace will light when the wall switch is turned on, and the burners will stay lit for anywhere from 30mins to a few hours. Then they will go out. The burners will come back on just by flipping the switch off then back on. Any advice?
October 28, 2013
Replace the switch
October 28, 2013
Majestic fireplace. We do turn off the pilot every summer because it generates too much heat for summers in CA. This year I have a problem. My pilot is nice and blue and hitting thermopile. Thermopile generates 460 mV. Main burner lights but is very low blue flame. It extinguishes within minutes and so does the pilot. I called a local majestic dealer but they are not on NFI list. I told them I think I might have a vent blockage and I’d like them to check the vent. The tech did no cleaning or service and nothing with the vent but pulled the flex line off the valve and said the supply flow is low based on how it sounded (no manometer). Spent 5 minutes and charged me for 30. Told me to call plumber. I did and manometer is within range for fireplace specs. Called dealer back and yelled at them a bit. Owner came this time. “Knows this fireplace like the back of his hand” yet put logs back wrong when he left for day. Told me pressure could be good in supply gas but flow could still be low. How can that be if gas is compressible? No luck with this. What could be wrong and who do I call for help? Pilot looks good but when burner is on (briefly), the flame appears to draw away from thermopile.
October 28, 2013
Try running the unit with the bottom of the glass frame cracked open. If it stays running, you can determine if its a venting issue.
A lot of these majestic fireplaces had collars up on top that would break loose and cause a leak in the firebox. Symptoms include the flame turning really blue and “ghosting” off the burner (burning up in the air) right before it went out.
Take the glass off and shine a flashlight up into the top of the firebox. Then look into the upper louver area from the outside. If you can see light shining through you know the collar has a leak. If it does, buy some high temp silicone and seal it up.
October 28, 2013
Majestic fireplace. We do turn off the pilot every summer because it generates too much heat for summers in CA. This year I have a problem. My pilot is nice and blue and hitting thermopile. Thermopile generates 460 mV. Main burner lights but is very low blue flame. It extinguishes within minutes and so does the pilot. I called a local majestic dealer but they are not on NFI list. I told them I think I might have a vent blockage and I’d like them to check the vent. The tech did no cleaning or service and nothing with the vent but pulled the flex line off the valve and said the supply flow is low based on how it sounded (no manometer). Spent 5 minutes and charged me for 30. Told me to call plumber. I did and manometer is within range for fireplace specs. Called dealer back and yelled at them a bit. Owner came this time. “Knows this fireplace like the back of his hand” yet put logs back wrong when he left for day. Told me pressure could be good in supply gas but flow could still be low. How can that be if gas is compressible? No luck with this. What could be wrong and who do I call for help? Pilot looks good but when burner is on (briefly), the flame appears to draw away from thermopile.
October 28, 2013
Try running the unit with the bottom of the glass frame cracked open. If it stays running, you can determine if its a venting issue.
A lot of these majestic fireplaces had collars up on top that would break loose and cause a leak in the firebox. Symptoms include the flame turning really blue and “ghosting” off the burner (burning up in the air) right before it went out.
Take the glass off and shine a flashlight up into the top of the firebox. Then look into the upper louver area from the outside. If you can see light shining through you know the collar has a leak. If it does, buy some high temp silicone and seal it up.
October 30, 2013
Thanks for the guidance. Don’t forget to check the connections under the firebox. After checking my wall switch, I reseated the flat clips and adjusted the wire down there and my flame popped on!
October 30, 2013
Thanks for the guidance. Don’t forget to check the connections under the firebox. After checking my wall switch, I reseated the flat clips and adjusted the wire down there and my flame popped on!
November 1, 2013
Do I need a gas fitter to replace the pilot assembly? Or, is this a DIY job?
Thanks for all the great info on this site!
November 4, 2013
It depends on your comfort level. Most pilot assemblies aren’t too difficult to replace, but some can be a pain.
November 1, 2013
Do I need a gas fitter to replace the pilot assembly? Or, is this a DIY job?
Thanks for all the great info on this site!
November 4, 2013
It depends on your comfort level. Most pilot assemblies aren’t too difficult to replace, but some can be a pain.
November 2, 2013
Our fireplace wouldn’t light for over a year. I just used this page, walked over snd flipped on the switch I never could figure out what it was for. Lol, the flame came right on.
November 2, 2013
Our fireplace wouldn’t light for over a year. I just used this page, walked over snd flipped on the switch I never could figure out what it was for. Lol, the flame came right on.
November 7, 2013
We have a superior gas fireplace. Pilot works fine. The switch works fine. The flames are only about two inches high. They used to work much better. Our furnace guy took the whole thing apart, cleaned out everything, and put it all back together. He also tested the gas line which checks out good. Still the same on the flame. Is this a valve issue?
November 12, 2013
Double check to make sure there is nothing the in burner tube connected to the valve. I’ve been on some service calls where the previous service tech did not go far enough down the burner tube to clear the obstruction.
To test the valve, make sure to test the incoming pressure (“in” screw on the valve) and outgoing pressure (“out” screw -which is right next to the “in” screw). To do this you will need a manometer (a device used to test gas pressure). On the rating place for the fireplace it should tell you what the inlet minimum and outlet minimum is supposed to be.
November 12, 2013
Retested the tube, completely clear. My HVAC guy took apart the lines and checked the pressure like you suggested. In was good, out was bad. That is when he determined something was wrong with the valve. He said the valve needs to be replaced. My question is – where do I get a replacement valve? I’ve looked all over and can’t seem to find a supplier for this valve.
November 14, 2013
Certain valves (ei Honeywell) are no longer made and can be almost impossible to find. Check with the local dealer that carries your fireplace brand. Many times, there is a conversion or a compatible valve that can be used instead.
November 7, 2013
We have a superior gas fireplace. Pilot works fine. The switch works fine. The flames are only about two inches high. They used to work much better. Our furnace guy took the whole thing apart, cleaned out everything, and put it all back together. He also tested the gas line which checks out good. Still the same on the flame. Is this a valve issue?
November 12, 2013
Double check to make sure there is nothing the in burner tube connected to the valve. I’ve been on some service calls where the previous service tech did not go far enough down the burner tube to clear the obstruction.
To test the valve, make sure to test the incoming pressure (“in” screw on the valve) and outgoing pressure (“out” screw -which is right next to the “in” screw). To do this you will need a manometer (a device used to test gas pressure). On the rating place for the fireplace it should tell you what the inlet minimum and outlet minimum is supposed to be.
November 12, 2013
Retested the tube, completely clear. My HVAC guy took apart the lines and checked the pressure like you suggested. In was good, out was bad. That is when he determined something was wrong with the valve. He said the valve needs to be replaced. My question is – where do I get a replacement valve? I’ve looked all over and can’t seem to find a supplier for this valve.
November 14, 2013
Certain valves (ei Honeywell) are no longer made and can be almost impossible to find. Check with the local dealer that carries your fireplace brand. Many times, there is a conversion or a compatible valve that can be used instead.
November 10, 2013
We just turned on the pilot light, and it worked. then we switched the valve to “on” and the fireplace started up without us turning the wall switch on. The wall switch wont control the fireplace, how do we fix it
November 12, 2013
There must be some other switch turning the control valve on. Is there anything else connected to the terminals (maybe on the back side of the terminals). Sometimes there is a toggle switch underneath the fireplace near the control valve that will also turn on and off the fireplace.
November 10, 2013
We just turned on the pilot light, and it worked. then we switched the valve to “on” and the fireplace started up without us turning the wall switch on. The wall switch wont control the fireplace, how do we fix it
November 12, 2013
There must be some other switch turning the control valve on. Is there anything else connected to the terminals (maybe on the back side of the terminals). Sometimes there is a toggle switch underneath the fireplace near the control valve that will also turn on and off the fireplace.
November 20, 2013
My wife and I are in a process of preparing to sell our rental property. One of the best features of the property is the gas fireplace in the recroom. We discovered that it is not working (pilot on but burner will not light up).
So my wife set an appointment with a repairman who came to inspect the fireplace, and promptly declared that we would have to replace the whole fireplace as it was fairly old and not worth it to repair.
I did some research and found this website. So I followed the instructions, checked the switch, pilot light and thermocouple/pile. I cleaned and vacuumed the dust as well as cleaned the glass while it was open, and lo and behold, my fireplace works as good as it ever did!
I have no idea how much money I saved, but I am sure it is a lot. Although I was taking my time, I spent no more than 30 minutes from start to finish, including vacuuming and carefully cleaning the glass.
Thank you very much!
November 20, 2013
My wife and I are in a process of preparing to sell our rental property. One of the best features of the property is the gas fireplace in the recroom. We discovered that it is not working (pilot on but burner will not light up).
So my wife set an appointment with a repairman who came to inspect the fireplace, and promptly declared that we would have to replace the whole fireplace as it was fairly old and not worth it to repair.
I did some research and found this website. So I followed the instructions, checked the switch, pilot light and thermocouple/pile. I cleaned and vacuumed the dust as well as cleaned the glass while it was open, and lo and behold, my fireplace works as good as it ever did!
I have no idea how much money I saved, but I am sure it is a lot. Although I was taking my time, I spent no more than 30 minutes from start to finish, including vacuuming and carefully cleaning the glass.
Thank you very much!
November 30, 2013
Thanks for the helpful info ,very easy to follow trouble shooting guidelines, turns the problem was the wall switch. Thanks again . P.S. Best of all the repair was free.
November 30, 2013
Thanks for the helpful info ,very easy to follow trouble shooting guidelines, turns the problem was the wall switch. Thanks again . P.S. Best of all the repair was free.
December 7, 2013
Pilot wouldn’t stay on so I replaced thermo couple. It still couldn’t get it to work so I cleaned the pilot assembly with a bruch and with the glass front off the pilot will turn on. Once I clamp the glass front back on the pilot goes out. Any ideas on this one?
Thanks for any help.
December 11, 2013
It sounds like its starving for air. Check for blockage in the flue (birds nests or bees nests are common) or a leak in the firebox. Shine a flashlight inside the firebox and see if you can see light shining through anywhere its not supposed to.
December 7, 2013
Pilot wouldn’t stay on so I replaced thermo couple. It still couldn’t get it to work so I cleaned the pilot assembly with a bruch and with the glass front off the pilot will turn on. Once I clamp the glass front back on the pilot goes out. Any ideas on this one?
Thanks for any help.
December 11, 2013
It sounds like its starving for air. Check for blockage in the flue (birds nests or bees nests are common) or a leak in the firebox. Shine a flashlight inside the firebox and see if you can see light shining through anywhere its not supposed to.
March 23, 2014
I just want to be among the many to thank you for your advice. Sure enough, the switch was at fault. I really appreciate the straight forward high quality help you have provided. Thanks again.
March 23, 2014
I just want to be among the many to thank you for your advice. Sure enough, the switch was at fault. I really appreciate the straight forward high quality help you have provided. Thanks again.
October 31, 2014
We are renting a property currently, and the main heat for the apartment is a free standing has fireplace (I.e. It isn’t insured into the wall). You push the button in, punch the ignite button and we found holding in “pilot” for about ten seconds will then allow us to turn the nob to light the main burners. However, after no more than a minute, there is a loud “clunk!” noise and the main burners turn off along with the piolet. What could be causing this? The thermopile? Or the pilot light, which is all blue but a large flame? Also, I know the man who rented this place before us had his gas totally shut off for two years (how he survived the winter, I’ll never know) so would that cause any of this?
November 12, 2014
Please follow the pilot light issues tutorial on the website. It sounds like there could be an issue with the pilot flame or the thermocouple.
Watch the pilot flame right before it goes out. Does it look like its pulling away from the thermocouple? This would mean you would need a new pilot assembly. If not, your thermocouple may be bad.
October 31, 2014
We are renting a property currently, and the main heat for the apartment is a free standing has fireplace (I.e. It isn’t insured into the wall). You push the button in, punch the ignite button and we found holding in “pilot” for about ten seconds will then allow us to turn the nob to light the main burners. However, after no more than a minute, there is a loud “clunk!” noise and the main burners turn off along with the piolet. What could be causing this? The thermopile? Or the pilot light, which is all blue but a large flame? Also, I know the man who rented this place before us had his gas totally shut off for two years (how he survived the winter, I’ll never know) so would that cause any of this?
November 12, 2014
Please follow the pilot light issues tutorial on the website. It sounds like there could be an issue with the pilot flame or the thermocouple.
Watch the pilot flame right before it goes out. Does it look like its pulling away from the thermocouple? This would mean you would need a new pilot assembly. If not, your thermocouple may be bad.
November 11, 2014
I have a Majestic Fireplace Model UVS33RN. The valve is bad and is the Honeywell one which has been discontinued. Is there anywhere at all I can locate the part. I contacted all the local dealers and was told I have to replace the entire unit including the mantel. Please help.
November 11, 2014
Unfortunately they are correct. Unless you can find the gas valve (maybe someone has one yet online somwehere) you will need to replace the fireplace.
November 11, 2014
I have a Majestic Fireplace Model UVS33RN. The valve is bad and is the Honeywell one which has been discontinued. Is there anywhere at all I can locate the part. I contacted all the local dealers and was told I have to replace the entire unit including the mantel. Please help.
November 11, 2014
Unfortunately they are correct. Unless you can find the gas valve (maybe someone has one yet online somwehere) you will need to replace the fireplace.
December 31, 2014
Does the unit turn on with a switch or manually with a knob? Is it a standing pilot log or an IPI unit?
December 31, 2014
Does the unit turn on with a switch or manually with a knob? Is it a standing pilot log or an IPI unit?
February 25, 2015
This post just saved me a lot of money. I have put off repairing my fireplace for a year and a half to save money, Turns out the connection to the wall switch was bad. Because of your thorough instructions, the fix took about 3 minutes. I really appreciate the assist.
February 26, 2015
Glad to have helped. Thanks for your feedback!
February 25, 2015
This post just saved me a lot of money. I have put off repairing my fireplace for a year and a half to save money, Turns out the connection to the wall switch was bad. Because of your thorough instructions, the fix took about 3 minutes. I really appreciate the assist.
February 26, 2015
Glad to have helped. Thanks for your feedback!
March 7, 2015
Getting dirty/dusty seemed to have been my problem. I simply jiggled the wires a bit and now it works fine.
March 7, 2015
Getting dirty/dusty seemed to have been my problem. I simply jiggled the wires a bit and now it works fine.
April 27, 2015
You just saved me $600 (at least). We bought a house with a gas fireplace and it wouldn’t come on, no pilot light even. Your videos and writing about how these fireplaces work gave me enough to figure out how to light the pilot and that our fireplace was controlled by a thermostat in the room and that there was a device (guessing some kind of amplifier) on the return from the thermostat to the stove (its a long run). Once I set the thermostat to on I went back and wiggled the connection on this amplifier and our stove came on!
This is all after I had a tech come out, charge me $125 for the visit and tell me that they couldn’t identify the exact issue and wanted to order a new thermocouple/thermopile AND a new SIT 820 main valve! Now that I’ve done this little fix myself, and knowing that you can easily pinpoint the problem with a multimeter I know these guys were crooks and they were going to take advantage of my prior ignorance.
THANK YOU!
April 27, 2015
You just saved me $600 (at least). We bought a house with a gas fireplace and it wouldn’t come on, no pilot light even. Your videos and writing about how these fireplaces work gave me enough to figure out how to light the pilot and that our fireplace was controlled by a thermostat in the room and that there was a device (guessing some kind of amplifier) on the return from the thermostat to the stove (its a long run). Once I set the thermostat to on I went back and wiggled the connection on this amplifier and our stove came on!
This is all after I had a tech come out, charge me $125 for the visit and tell me that they couldn’t identify the exact issue and wanted to order a new thermocouple/thermopile AND a new SIT 820 main valve! Now that I’ve done this little fix myself, and knowing that you can easily pinpoint the problem with a multimeter I know these guys were crooks and they were going to take advantage of my prior ignorance.
THANK YOU!
May 1, 2015
You would need to use something that doesn’t require power for operation. Look for something that uses thermostat wire or says for millivolt systems.
May 1, 2015
You would need to use something that doesn’t require power for operation. Look for something that uses thermostat wire or says for millivolt systems.
January 14, 2016
What you should do is have a icon on your website where readers and ultimately self repair people could donate to your cause.
The amount of money you have saved me would be well worth a few dollars sent your way.
January 17, 2016
I tried to donate, but the link does not work.
January 19, 2016
Thank you for your feedback! The link should be working now.
January 14, 2016
What you should do is have a icon on your website where readers and ultimately self repair people could donate to your cause.
The amount of money you have saved me would be well worth a few dollars sent your way.
January 17, 2016
I tried to donate, but the link does not work.
January 19, 2016
Thank you for your feedback! The link should be working now.
January 17, 2016
I’d like to add a 5th category to your list which is “the gas orifices are clogged with dust/dirt/debris. Try blowing them out with compressed air”. That fixed my fireplace!
January 17, 2016
I’d like to add a 5th category to your list which is “the gas orifices are clogged with dust/dirt/debris. Try blowing them out with compressed air”. That fixed my fireplace!
February 13, 2016
My wall switch looks like this – which does not resemble the photo you posted.
What are all these extra wires?
Pilot light works fine – burner does not turn on. This outlet has looked like this since we moved in – never had a switch, so I’m trying to figure out how to get it running. Any help is so appreciated! THANKS!!
February 13, 2016
My wall switch looks like this – which does not resemble the photo you posted.
What are all these extra wires?
Pilot light works fine – burner does not turn on. This outlet has looked like this since we moved in – never had a switch, so I’m trying to figure out how to get it running. Any help is so appreciated! THANKS!!
February 28, 2016
Commercial grade switches from Leviton have silver alloy switch contacts and can be purchased for less than $10 from home centers. This is the most reliable and economic solution if you determine the problem is the switch.
The silver does not build up residue like the brass contacts on standard grade switches.
February 28, 2016
Commercial grade switches from Leviton have silver alloy switch contacts and can be purchased for less than $10 from home centers. This is the most reliable and economic solution if you determine the problem is the switch.
The silver does not build up residue like the brass contacts on standard grade switches.
November 18, 2017
Rust, corrosion, or buildup on the pilot hood can cause a weak pilot flame. I would recommend replacing the pilot assembly. Alternatively you can take the pilot assembly apart and try to clean it with a wire brush to help the pilot flame to look better.
November 20, 2017
Spiderweb
November 18, 2017
Rust, corrosion, or buildup on the pilot hood can cause a weak pilot flame. I would recommend replacing the pilot assembly. Alternatively you can take the pilot assembly apart and try to clean it with a wire brush to help the pilot flame to look better.
November 20, 2017
Spiderweb
November 18, 2017
I would start by removing the high/low knob and make sure there is a rubber diaphram/gasket to seal it to the old valve. There should only be 1 gasket (the original one should be removed and the one supplied with the conversion kit installed). Also make sure when the regulator is re-installed it is screwed in as tight as you can.
November 18, 2017
I would start by removing the high/low knob and make sure there is a rubber diaphram/gasket to seal it to the old valve. There should only be 1 gasket (the original one should be removed and the one supplied with the conversion kit installed). Also make sure when the regulator is re-installed it is screwed in as tight as you can.
November 19, 2017
Thanks very much, followed steps and it was a bad thermostat. Easy fix!
November 19, 2017
Thanks very much, followed steps and it was a bad thermostat. Easy fix!
December 15, 2017
Just a bad switch. Thanks bud
February 19, 2018
Glad you were able to figure it out!
December 15, 2017
Just a bad switch. Thanks bud
February 19, 2018
Glad you were able to figure it out!
February 19, 2018
With this model fireplace, the “IPI” part stands for “intermittent pilot ignition” This means its electronic ignition and does not have a pilot light that runs constantly. It should just turn on with the wall switch (you should not need to turn on the pilot light). It sounds like its functioning properly.
February 19, 2018
It was a problem with the modul, which I replaced (after replacing the pilot assembly), and now works perfect. It was an electronics problem.
February 19, 2018
With this model fireplace, the “IPI” part stands for “intermittent pilot ignition” This means its electronic ignition and does not have a pilot light that runs constantly. It should just turn on with the wall switch (you should not need to turn on the pilot light). It sounds like its functioning properly.
February 19, 2018
It was a problem with the modul, which I replaced (after replacing the pilot assembly), and now works perfect. It was an electronics problem.